Chip: |
Felica LITE S |
Frequency: |
13.56MHz |
Protocal: |
ISO/IEC 18092 |
Memory: |
2K bytes |
Read/Write Times: |
100,000 times |
Working Life: |
10 years |
Size: |
25mm diameter, 25×38mm (Depends on Request) |
Thickness: |
0.3 ~ 0.8mm |
Material: |
PVC/PET/Coated Paper |
Antenna: |
Aluminium Foil |
Reading Distance: |
1-10cm(Depends on the card reader and antenna) |
Working Tmeperature: |
-45℃ ~ 85℃ |
Storage Temperature: |
-20℃ ~ 45℃ |
Available Crafts: |
Printing and laser logo, Bar code and Serial numbers, etc. |
Quality doesn’t come from inspection, even we do 100% inspection for each item!
Quality comes from advanced design and strict control during manufacturing process!!
In order you know exactly performance of such product, we will show our lab testing to measure key parameters, including Resonance Frequency, Q Value, Read/Write Distance, Protocol, UID etc.
Network Analyzer
Model: Anritsu MS4630B
Frequency Range: 10HZ-300MHz
Frequency |
Range: 10 HZ to 300MHZ Resolotion: 0.01HZ Accurancy(standard) Aging rate:≤1×10-6/day(15 minutes after power-on) Temperature characteristics:≤±5×10-6(0 to +50℃) Accurancy(Option 13: High stability refrence oscillator) Aging rate:≤1×10-8/day(15 minutes after power-on) Temperature characteristics:≤±5×10-8(0 to +50℃) |
Main measurement parameter: Resonance Frequency, Q Value
Testing Results
|
Sample 1
|
Sample 2
|
Sample 3
|
Sample 4
|
Sample 5
|
Resonance Frequency
|
13.31MHz |
13.34MHz |
13.34MHz |
13.31MHz |
13.31MHz |
HF RFID Tag Tester
Model: FQ-5X-U
Frequency Range: 1-30MHz
Use this device to measure: RF Functionality, Resonance Frequency, Q Value, RF Protocol
Testing Results
|
Sample 1
|
Sample 2
|
Sample 3
|
Sample 4
|
Sample 5
|
Resonance Frequency
|
13.62MHz |
13.58MHz |
13.63MHz |
13.50MHz |
13.61MHz |
Q value
|
20 |
24 |
25 |
13 |
27 |
Protocol
|
ISO14443A |
ISO14443A |
ISO14443A |
ISO14443A |
ISO14443A |
UID
|
04 1E 4D 9A 98 3C 81 |
04 25 4D 9A 98 3C 81 |
04 12 4D 9A 98 3C 81 |
04 18 4D 9A 98 3C 81 |
04 24 4D 9A 98 3C 81 |
Handheld RFID Card/Tag Reader
Model………………………………………
Power: ……………………………………….
Support Protocol: ISO 14443/15693/NFC etc.
Use this reader to do RF function testing and reading distance measurement.
Testing Results
|
Sample 1
|
Sample 2
|
Sample 3
|
Sample 4
|
Sample 5
|
RF Functionality
|
Yes |
Yes |
Yes |
Yes |
Yes |